Valve Proving Controls TC 1-3
- Adjustable test period which can be adapted to different systems
- Adjustable test mode allows quick system start
- Maximum safety thanks to self-monitoring electronics
- Explore our limited stock of hard-to-find models
Learn More:
Description Documentation Ordering Information Accessories
Ordering Information
| Model and Description | Price | Cart |
| TC 2N05Q/Q Type: 2; Mounting: NPT internal thread; Connection: 8 mm, ¼″ (0,31″); Pressure: pe max. 500 mbar (7.25 psig) |
Contact Us | Not available for online purchase. |
| TC 3N05Q/Q Type: 3; Mounting: NPT internal thread; Connection: 8 mm, ¼″ (0,31″); Pressure: pe max. 500 mbar (7.25 psig) |
Contact Us | Not available for online purchase. |
|
||||||||||
| Model and Description | Stock | Price | Cart | |||||||
| TC 218TN05-N Tightness control; for checking two safety valves, with adjustable test period (10 to 60 s) for adjustment to different test volumes, leakage rates and inlet pressures, FM tested; Version 2; Testing before or after burner run; NPT internal thread; pu max. 200 "WC (500 mbar); main voltage: 110/120 VAC |
||||||||||
Description
The tightness control TC checks the fail-safe function of both valves before each start-up or after each shut-down of a system with two safety valves.
The aim is to identify an inadmissible leak on one of the gas valves and to prevent burner start. The other gas valve continues working properly and takes over the safe shut-off of the gas supply.
It is used in industrial thermoprocessing equipment, on boilers and on forced draught burners.
Standards ISO 13577-2, EN 746-2 and EN 676 stipulate tightness controls for capacities over 1200 kW (NFPA 86: from 117 kW or 400,000 Btu/h in conjunction with a visual indicator).
Pre-purge of the combustion chamber can be dispensed with under certain conditions in accordance with EN 746-2 if a tightness control is used. In this case, the system must be vented into a safe area.
TC 1V, TC 1C
Tightness control TC 1V can be directly flange-mounted to all valVario controls. There is only only one version for all sizes. TC 1C can be used for combination controls CG 1 to 3. An adapter plate is supplied for installation
TC 2
Tightness control TC 2 can be used with gas solenoid valves of any nominal size, which are quick opening or slow opening with start rate. It is possible to conduct a tightness test on pneumatically operated or slow opening valves without start rate by using additional auxiliary valves.
Slow opening motorized valves VK up to DN 65 which are directly flanged together can also be checked by the TC 2 within a temperature range of 0 to 60°C (32 to 140°F). An adapter plate is provided for installation of the TC 2.
TC 3
Tightness control TC 3 is a universal device for quick and slow opening gas solenoid valves of any nominal size as well as for motorized valves. The tightness test is carried out with the valves installed in the TC 3.
Documentation
| FAQ: Kromschröder Product Labels and Type Codes (Blog Post) | |
| Valve Proving Control TC 1-3 Brochure | |
| Valve Proving Control TC 1-3 Installation Instructions | |
| Valve Proving Control TC 1-3 Technical Sheet |