SubTotal: 
  
Combustion 911
Supplying and Serving the Combustion Industry
an Olsträd Engineering Company

Site Search

Industrial Ribbon Linear Flame Burners for Gas AB and ABMIndustrial Ribbon Linear Flame Burners for Gas AB and ABM

The ribbon burners AB and ABM are premixed linear flame burners used in low temperature applications for many different thermal industrial requirements. The special shape of the ribbon guarantees excellent flame stability even in combustion chambers with internal recirculation. The AB series of burners must be connected to an air/gas mixer that guarantees the correct combustion ratio. The ABM series of burners have an air/gas mixer incorporated inside the furnace flange. The mixing flange is patented for this use (n°259843 – MI2004U000376).

The linear flame burners are also available in special designs according to geometric and application parameters provided by the end user.

Characteristics:

  • Flow ratio = 1:5

Applications:

  • Environment heating
  • Furnaces and ovens for cooking food
  • Vial sterilizing machines
  • Industrial packaging machines
  • Flame screens
  • Brazing machines

Description

The AB/ABM RIBBON burner ignition takes place via a high voltage discharge supplied by special electrode. The standard configuration has mono-electrode flame detection. Flame detection can take place, on request, with separate electrode or UV flame detector.

Ordering Information

Model and Description Model Flame Tube
Diameter
Capacity Ignition Detection Price Cart
8AB
Flame Tube diameter: Ø 1”; Capacity: 68K Btu/Hr; Ignition: Direct Spark; Detection: Flame Rod or UV
8AB Ø 1” 68K Btu/Hr Direct Spark Flame Rod or UV Contact Us Not available for online purchase.
10AB
Flame Tube diameter: Ø 1-1/4”; Capacity: 85K Btu/Hr; Ignition: Direct Spark; Detection: Flame Rod or UV
10AB Ø 1-1/4” 85K Btu/Hr Direct Spark Flame Rod or UV Contact Us Not available for online purchase.
12AB/12ABM
Flame Tube diameter: Ø 1-1/2”; Capacity: 100K Btu/Hr; Ignition: Direct Spark; Detection: Flame Rod or UV
12AB/12ABM Ø 1-1/2” 100K Btu/Hr Direct Spark Flame Rod or UV Contact Us Not available for online purchase.
16AB/16ABM
Flame Tube diameter: Ø 2”; Capacity: 140K Btu/Hr; Ignition: Direct Spark; Detection: Flame Rod or UV
16AB/16ABM Ø 2” 140K Btu/Hr Direct Spark Flame Rod or UV Contact Us Not available for online purchase.
20AB/20ABM
Flame Tube diameter: Ø 2-1/2”; Capacity: 220K Btu/Hr; Ignition: Direct Spark; Detection: Flame Rod or UV
20AB/20ABM Ø 2-1/2” 220K Btu/Hr Direct Spark Flame Rod or UV Contact Us Not available for online purchase.

For all other configurations and spare parts Contact Combustion 911

Accessories

Model and Description Price Cart
Ignition Cable
Silicone Rubber Cable High Voltage 7mm (priced per foot).

 

Industrial Ribbon Linear Flame Burners for Gas AB and ABM

 

Combustion 911 Blog Blog Home   Combustion 911 RSS Feed RSS feed
Top