Enclosed Ignition Transformer TGI

  • Electrical ignition of gas burners
  • Ignition and flame sensing with a single electrode possible
  • IP65, NEMA 4 enclosure
  • TGI..T is UL recognized, USA and Canada
Ignition Transformer TGI

Learn More:
Description   Documentation   Ordering Information   Accessories

Ordering Information

   

Alternate Product

Model and
Description
Model High Voltage Output Current Mains voltage Duty Cycle SEO* Price Order   Model Inventory Price Order
TGI 8-20/19QT
High voltage: 1x8 kV kV; Output current: 20 mA; Mains Voltage: 115V; Duty Cycle: 19%
TGI 8-20/19QT 1x8 kV 20mA 115V 19% Yes Contact Us   C911-X820-1
, TGI 5-15/100QT
High voltage: 1x5 kV; Output current: 15 mA; Mains Voltage: 115V; Duty Cycle: 100%
TGI 5-15/100QT 1x5 kV 15 mA 115V 100% Yes Contact Us  
TGI 8-20/33QT
High voltage: 1x8 kV; Output current: 20 mA; Mains Voltage: 115V; Duty Cycle: 33%
TGI 8-20/33QT 1x8 kV 20 mA 115V 33% Yes Contact Us  
TGI 8-12/100QT
High voltage: 1x8 kV; Output current: 12 mA; Mains Voltage: 115V; Duty Cycle: 100%
TGI 8-12/100QT 1x8 kV 12 mA 115V 100% Yes Contact Us  

* SEO = Single Electrode Operation

Description

Ignition transformers TZI and TGI are designed for high-voltage spark ignition of gas burners with a single-pole output to protective earth (PE). The ignition transformers can also be used on burners with single-electrode operation (SEO); the ignition current and ionization current flow over a common electrode. Ignition transformer TZI must be mounted in a non-contact housing, for example in a control cabinet. It fulfills the requirements for IP 00. Ignition transformer TGI in its die-cast aluminum housing meets the requirements for enclosure IP 65, NEMA 4. It is suitable for on-site mounting near the burner.

Duty Cycles

Transformers can operate, depending on the model, on continuous or intermittent duty in accordance with the technology applied to the burner and the control device. Intermittent duty transformers are designed for specific ON and OFF times. Please check the label of the transformer in question. Note, the duty cycle decreases proportionately if the transformer is subject to ambient temperatures in excess of the design spec., which is 35°C (95°F) in this case.


ED=19% on 3 min. (180s)
The transformer can operate for 34 seconds and should be turned off for the remaining 146 seconds. Since the transformer is only active during burner ignition, and assuming a 5 second spark time, it appears the transformer can attempt six burner ignition trials in 180 seconds, or two per minute.

ED=33% on 3 min.
This notation means the transformer can be switched ON for one minute, and must then be OFF for at least two minutes.

ED=100%
These transformers can operate continuously.

Accessories

Model and Description Price Cart
04115301
4mm Right-angle Electrode Boot; spiked cable end
04115308
4mm Right-angle Electrode Boot; screw cable end
04115302
4mm Straight Electrode Boot; screw cable end
04115306
6mm Straight Electrode Boot; screw cable end
04115309
4mm Right-angle Electrode Boot; screw cable end
04115314
4mm Straight Electrode Boot; screw cable end
75459221
4mm Right-angle Electrode Boot; screw cable end
Ignition Cable
Silicone Rubber Cable High Voltage 7mm (priced per foot).
 
 

Combustion 911

600 Mogadore Rd. Kent, OH 44240

Phone 330-678-4328

Email: support_ab@combustion911.com

View Terms and Conditions

Privacy Policy

©2026 Olstrad Corporation All Rights Reserved

Visit Combustion 911 on LinkedInVisit Combustion 911 on FacebookVisit Combustion 911 on TwitterWatch Combustion 911 videos on YouTubeEmail Combustion 911Read Articles on the Combustion 911 Blog
Olstrad Corporation

Need a quote? Have a Question?


 
➤