SubTotal: 
  
Combustion 911
Supplying and Serving the Combustion Industry
an Olsträd Engineering Company

Site Search

Butterfly Valve BVGButterfly Valve for Gas and Air BVG

  • For gas, air, hot air and flue gas
  • Low leakage rate and pressure loss
  • High control accuracy
  • Reduced nominal diameters
  • Can be mounted directly onto the actuators IC 20 or IC 40
  • Suitable for intermittent operation
  • Low-maintenance operation

Description

The butterfly valves BVG, BVH, BVHM and BVHS are designed to adjust volumes of gas, cold and hot air, and flue gas on various appliances and flue gas lines. They are designed for control ratios up to 1:10, and with the mounted actuator IC 20 or IC 40 they are suitable for regulating flow rates for modulating or stage-controlled combustion processes.

Flow rates can be set and fixed using a lever, for example to limit the high-fire rate on the burner. A scale indicates the set angle of opening.

The BVG is a butterfly valve with reduced nominal diameter (reduced by one or two nominal sizes) and can be used to achieve higher control accuracy. This will mean that complex reducing fittings will no longer be required.

Ordering Information

Model and Description Model Bore Diameter Max inlet pressure Connection Fitting Price Cart
BVG 40W05
Bore diameter: 1½″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (1½″)
BVG 40W05 1½″ 500 mbar (7.25 psig) between two ANSI flanges (1½″)
BVG 50W05
Bore diameter: 2″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2″)
BVG 50W05 2″ 500 mbar (7.25 psig) between two ANSI flanges (2″)
BVG 65W05
Bore diameter: 2½″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2½″)
BVG 65W05 2½″ 500 mbar (7.25 psig) between two ANSI flanges (2½″)
BVG 80W05
Bore diameter: 3″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (3″)
BVG 80W05 3″ 500 mbar (7.25 psig) between two ANSI flanges (3″)
BVG 100W05
Bore diameter: 4″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (4″)
BVG 100W05 4″ 500 mbar (7.25 psig) between two ANSI flanges (4″)
BVG 40/32W05
Bore diameter: 1¼″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (1½″)
BVG 40/32W05 1¼″ (reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (1½″)
BVG 50/40W05
Bore diameter: 1½″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2″)
BVG 50/40W05 1½″ (reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (2″)
BVG 65/50W05
Bore diameter: 2″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2½″)
BVG 65/50W05 2″ (reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (2½″)
BVG 80/65W05
Bore diameter: 2½″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (3″)
BVG 80/65W05 2½″ (reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (3″)
BVG 100/80W05
Bore diameter: 3″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (4″)
BVG 100/80W05 3″ (reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (4″)
BVG 40/25W05
Bore diameter: 1″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (1½″)
BVG 40/25W05 1″ (2 × reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (1½″)
BVG 50/32W05
Bore diameter: 1¼″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2″)
BVG 50/32W05 1¼″ (2 × reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (2″)
BVG 65/40W05
Bore diameter: 1½″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2½″)
BVG 65/40W05 1½″ (2 × reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (2½″)
BVG 80/50W05
Bore diameter: 2″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (3″)
BVG 80/50W05 2″ (2 × reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (3″)
BVG 100/65W05
Bore diameter: 2½″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (4″)
BVG 100/65W05 2½″ (2 × reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (4″)

BVA models are no longer sold - the BVG replaces all BVA parts. BVG valves are rated for both gas and air.

Accessories

Model and Description Price Cart
BVG ACC 01
Adapter set BVG with square shaft /B
BVG ACC 02
Adapter set BVG with free shaft end /B
BVG ACC 03
Adapter set BVG with manual adjustment /B
IC-20/40 ACC 01
Fastening set IC-BVG/BVA/BVH/LFC /B

Jump to BVG model page

Model:

Click Here for Help choosing which model you need.
(Click here to Close)

Select Connection Type

  All Products
Normal bore
Reduced bore
2× reduced bore
Adapter sets
BVG 40W05
Price:
Bore diameter: 1½″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (1½″
BVG 50W05
Price:
Bore diameter: 2″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2″)
BVG 65W05
Price:
Bore diameter: 2½″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2½″)
BVG 80W05
Price:
Bore diameter: 3″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (3″)
BVG 100W05
Price:
Bore diameter: 4″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (4″)
BVG 40/32W05
Price:
Bore diameter: 1¼″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (1½″)
BVG 50/40W05
Price:
Bore diameter: 1½″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2″)
BVG 65/50W05
Price:
Bore diameter: 2″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2½″)
BVG 80/65W05
Price:
Bore diameter: 2½″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (3″)
BVG 100/80W05
Price:
Bore diameter: 3″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (4″)
BVG 40/25W05
Price:
Bore diameter: 1″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (1½″)
BVG 50/32W05
Price:
Bore diameter: 1¼″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2″)
BVG 65/40W05
Price:
Bore diameter: 1½″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2½″)
BVG 80/50W05
Price:
Bore diameter: 2″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (3″)
BVG 100/65W05
Price:
Bore diameter: 2½″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (4″)
BVG ACC 01
Price:
Adapter set BVG with square shaft /B
BVG ACC 02
Price:
Adapter set BVG with free shaft end /B
BVG ACC 03
Price:
Adapter set BVG with manual adjustment /B

Latest Blog Post

  • Use the ZI-808 From the Internet
    One of the most exciting features of the ZI-808 is its built-in web server. Its user interface is designed like a standard web page and embedded into the instrument. That means that any device that can open a web page can use it. Desktop, laptop, tablet, smart phone, Android, Windows, iOS, Linux, Edge, IE, Chrome, Firefox. read full post