Automatic Burner Control Unit IFS 110IMAutomatic Burner Control Unit IFS 110IM
This item is Discontinued

  • Flame control by means of flame rod or UV-detector
  • Flame simulation check before starting and after switching the burner off
  • Suitable for ignition and ionization control with one electrode
  • Modern technique using semiconductors
  • High cycling frequency
  • Remote reset
  • External fault indication
  • FM approved

Description

This automatic burner control unit is for monitoring and controlling gas burners. It can be used for intermittent operation, with ionization or UV control, single-electrode operation possible, multi-flame control possible, FM approved.

Ordering Information

Model and Description Model Trial for Ignition Period Mains Voltage Restart Following Flame Failure? Cart
IFS 110IMT-3/2/2N
3 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; No restart following flame failure.
IFS 110IMT-3/2/2N 3 seconds 110/120 V AC, 50/60 Hz No Discontinued
IFS 110IMT-5/2/2N
5 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; No restart following flame failure.
IFS 110IMT-5/2/2N 5 seconds 110/120 V AC, 50/60 Hz No Discontinued
IFS 110IMT-10/2/2N
10 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; No restart following flame failure.
IFS 110IMT-10/2/2N 10 seconds 110/120 V AC, 50/60 Hz No Discontinued
IFS 110IMT-W-3/2/2N
3 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; Restarts following flame failure.
IFS 110IMT-W-3/2/2N 3 seconds 110/120 V AC, 50/60 Hz Yes Discontinued
IFS 110IMT-W-5/2/2N
5 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; Restarts following flame failure.
IFS 110IMT-W-5/2/2N 5 seconds 110/120 V AC, 50/60 Hz Yes Discontinued
IFS 110IMT-W-10/2/2N
10 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; Restarts following flame failure.
IFS 110IMT-W-10/2/2N 10 seconds 110/120 V AC, 50/60 Hz Yes Discontinued

Accessories

No Accessories

Jump to IFS 110IM model page

Model:

Click Here for Help choosing which IFS 110IM Burner Control you need.
(Click here to Close)

Select desired characteristic

All Products
3 sec. Trial
5 sec. Trial
10 sec. Trial
Restarts after failure
Does not restart
IFS 110IMT-3/2/2N
Description: 3 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; No restart following flame failure.
IFS 110IMT-5/2/2N
Description: 5 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; No restart following flame failure.
IFS 110IMT-10/2/2N
Description: 10 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; No restart following flame failure.
IFS 110IMT-W-3/2/2N
Description: 3 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; Restarts following flame failure.
IFS 110IMT-W-5/2/2N
Description: 5 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; Restarts following flame failure.
IFS 110IMT-W-10/2/2N
Description: 10 second trial for ignition period; Mains voltage: 110/120 V AC, 50/60 Hz; Restarts following flame failure.

 