SubTotal: 
  
Combustion 911
Supplying and Serving the Combustion Industry
an Olsträd Engineering Company

Site Search

Learn More About...

Kromschroder Actuator IC 50

Actuator IC 50-07Q7E

Price:
Quantity:
  • Running time: 7 seconds/90°
  • Mains voltage: 120 V AC, 50/60 Hz
  • Torque: 7Nm
  • Controlled by continuous signal
  • Easy to switch between Automatic and Manual mode
  • Display of valve position
  • Selectable direction of rotation
  • Adjustable motor behaviour in the event of cable discontinuity
  • Actuator can be mounted directly onto the butterfly valves DKR

Accessories

Model and Description Price Cart
IC 50 ACC 01
Wall mounting bracket, IC 50 /B
IC 50 ACC 02
Attachment set IC 50-DKR Axial DN 15-20 /B
IC 50 ACC 03
Attachment set IC 50-DKR Axial DN 25-32 /B
IC 50 ACC 04
Attachment set IC 50-DKR Axial DN 40-50 /B
IC 50 ACC 05
Attachment set IC 50-DKR Axial DN 65-125 /B
IC 50 ACC 06
Attachment set IC 50-DKR Axial DN 150-250 /B
IC 50 ACC 07
Attachment set IC 50-DKR Axial DN 300 /B
IC 50 ACC 08
Attachment set IC 50-DKR Axial DN 350 /B
IC 50 ACC 09
Attachment set IC 50-DKR Axial DN 400-500 /B
IC 50 ACC 10
Attachment set IC 50-DKR..D DN 15-20 with linkage /B
IC 50 ACC 11
Attachment set IC 50-DKR..D DN 25-32 with linkage /B
IC 50 ACC 12
Attachment set IC 50-DKR..D DN 40-50 with linkage /B
IC 50 ACC 13
Attachment set IC 50-DKR..D DN 65-100 with linkage /B
IC 50 ACC 14
Attachment set IC 50-DKR..D DN 125 with linkage /B
IC 50 ACC 15
Attachment set IC 50-DKR..D DN 150-250 with linkage /B
IC 50 ACC 16
Attachment set IC 50-DKR..D DN 300 with linkage /B
IC 50 ACC 17
Attachment set IC 50-DKR..D DN 350 with linkage /B
IC 50 ACC 18
Attachment set IC 50-DKR..D DN 400-500 with linkage /B
IC 50 ACC 19
Attachment set IC 50-DKR..A DN 25-32 with shock suppressor /B
IC 50 ACC 20
Attachment set IC 50-DKR..A DN 40-50 with shock suppressor /B
IC 50 ACC 21
Attachment set IC 50-DKR..A DN 65-100 with shock suppressor /B
IC 50 ACC 22
Attachment set IC 50-DKR..A DN 125 with shock suppressor /B
IC 50 ACC 23
Attachment set IC 50-DKR..A DN 150-250 with shock suppressor /B
IC 50 ACC 24
Attachment set IC 50-DKR..A DN 300 with shock suppressor /B
IC 50 ACC 25
Attachment set IC 50-DKR..A DN 350 with shock suppressor /B
IC 50 ACC 26
Attachment set IC 50-DKR..A DN 400-500 with shock suppressor /B
For all other accessories Contact Combustion 911

Applications

Click on images for close-up view.

Application for Actuator IC 50 Modulating control via three-point step signal

For processes that require high temperature accuracy and low circulation in the furnace. Actuator IC is controlled by a three-point step controller and moves the butterfly valve to the ignition position. The burner starts. The butterfly valve opens or closes between the low-fire/high-fire rate positions depending on the capacity demand of the burner. When the three-point step signal is disconnected, the butterfly valve stops at its current position.
Application for Actuator IC 50 IC 50, three-point step control with burner control unit BCU.

The BCU moves the butterfly valve to pre-purge and ignition positions. After pre-purge and burner start, the controller enable signal is issued to an external three-point step controller which positions the butterfly valve in accordance with the capacity demand. Once the pre-purge or ignition position has been reached, a feedback signal is sent to the BCU.
Application for Actuator IC 50 IC 50..E, continuous control with burner control unit BCU

The BCU controls pre-purge and moves the butterfly valve to pre-purge and ignition positions. Once the BCU has started the burner, the modulation enable signal is issued via terminal 5 (OK). Actuator IC 50..E reacts to the (0) 4 – 20 mA or 0 – 10 V setpoint specification signals.

Specifications

Mains voltage: 120 V AC, -15/+10%, 50/60 Hz
Power consumption: 16 VA at 60 Hz, 13 VA at 50 Hz
Angle of rotation: 0 – 90°, adjustable.
Running time: 7 seconds/90°
Holding torque: 7 Nm
Typical designed lifetime:
Switching
current
Switching cycles
cos φ = 1 cos φ = 0.3
1 mA 1,000,000 --
22 mA -- 1,000,000
100 mA 1,000,000 --
2 A 100,000 --
Enclosure: IP 65
Safety class: I
Electrical connection: Line entrance: 3 × M20 plastic screw connectors.
Ambient temperature: -20 to 60°C, no condensation permitted.
Storage temperature: -20 to 40°C

Jump to IC 50 model page

Model:

Click Here for Help choosing which IC 50 model you need.
(Click here to Close)

Select desired characteristic

All Products
IC 50 Products
Three-point step control
Controlled by continuous signal
Accessories
IC 50-03Q3TR10
Price:
Description: 3.7 seconds/90°; Mains voltage: 120 V AC, 50/60 Hz; Torque: 3 Nm; w/ Three-point step control; w/ 1000 Ω feedback potentiometer.
IC 50-07Q7TR10
Price:
Description: 7 seconds/90°; Mains voltage: 120 V AC, 50/60 Hz; Torque: 7 Nm; w/ Three-point step control; w/ 1000 Ω feedback potentiometer.
IC 50-15Q15TR10
Price:
Description: 15 seconds/90°; Mains voltage: 120 V AC, 50/60 Hz; Torque: 15 Nm; w/ Three-point step control; w/ 1000 Ω feedback potentiometer.
IC 50-30Q20TR10
Price:
Description: 30 seconds/90°; Mains voltage: 120 V AC, 50/60 Hz; Torque: 20 Nm; w/ Three-point step control; w/ 1000 Ω feedback potentiometer.
IC 50-60Q30TR10
Price:
Description: 60 seconds/90°; Mains voltage: 120 V AC, 50/60 Hz; Torque: 30 Nm; w/ Three-point step control; w/ 1000 Ω feedback potentiometer.
IC 50-03Q3E
Price:
Description: 3.7 seconds/90°; Mains voltage: 120 V AC, 50/60 Hz; Torque: 3 Nm; Controlled by continuous signal.
IC 50-07Q7E
Price:
Description: 7 seconds/90°; Mains voltage: 120 V AC, 50/60 Hz; Torque: 7 Nm; Controlled by continuous signal.
IC 50-15Q15E
Price:
Description: 15 seconds/90°; Mains voltage: 120 V AC, 50/60 Hz; Torque: 15 Nm; Controlled by continuous signal.
IC 50-30Q20E
Price:
Description: 30 seconds/90°; Mains voltage: 120 V AC, 50/60 Hz; Torque: 20 Nm; Controlled by continuous signal.
IC 50-60Q30E
Price:
Description: 60 seconds/90°; Mains voltage: 120 V AC, 50/60 Hz; Torque: 30 Nm; Controlled by continuous signal.
IC 50 ACC 01
Price:
Description: Wall mounting bracket, IC 50 /B.
IC 50 ACC 02
Price:
Description: Attachment set IC 50-DKR Axial DN 15-20 /B
IC 50 ACC 03
Price:
Description: Attachment set IC 50-DKR Axial DN 25-32 /B
IC 50 ACC 04
Price:
Description: Attachment set IC 50-DKR Axial DN 40-50 /B
IC 50 ACC 05
Price:
Description: Attachment set IC 50-DKR Axial DN 65-125 /B
IC 50 ACC 06
Price:
Description: Attachment set IC 50-DKR Axial DN 150-250 /B
IC 50 ACC 07
Price:
Description: Attachment set IC 50-DKR Axial DN 300 /B
IC 50 ACC 08
Price:
Description: Attachment set IC 50-DKR Axial DN 350 /B
IC 50 ACC 09
Price:
Description: Attachment set IC 50-DKR Axial DN 400-500 /B
IC 50 ACC 10
Price:
Description: Attachment set IC 50-DKR..D DN 15-20 with linkage /B
IC 50 ACC 11
Price:
Description: Attachment set IC 50-DKR..D DN 25-32 with linkage /B
IC 50 ACC 12
Price:
Description: Attachment set IC 50-DKR..D DN 40-50 with linkage /B
IC 50 ACC 13
Price:
Description: Attachment set IC 50-DKR..D DN 65-100 with linkage /B
IC 50 ACC 14
Price:
Description: Attachment set IC 50-DKR..D DN 125 with linkage /B
IC 50 ACC 15
Price:
Description: Attachment set IC 50-DKR..D DN 150-250 with linkage /B
IC 50 ACC 16
Price:
Description: Attachment set IC 50-DKR..D DN 300 with linkage /B
IC 50 ACC 17
Price:
Description: Attachment set IC 50-DKR..D DN 350 with linkage /B
IC 50 ACC 18
Price:
Description: Attachment set IC 50-DKR..D DN 400-500 with linkage /B
IC 50 ACC 19
Price:
Description: Attachment set IC 50-DKR..A DN 25-32 with shock suppressor /B
IC 50 ACC 20
Price:
Description: Attachment set IC 50-DKR..A DN 40-50 with shock suppressor /B
IC 50 ACC 21
Price:
Description: Attachment set IC 50-DKR..A DN 65-100 with shock suppressor /B
IC 50 ACC 22
Price:
Description: Attachment set IC 50-DKR..A DN 125 with shock suppressor /B
IC 50 ACC 23
Price:
Description: Attachment set IC 50-DKR..A DN 150-250 with shock suppressor /B
IC 50 ACC 24
Price:
Description: Attachment set IC 50-DKR..A DN 300 with shock suppressor /B
IC 50 ACC 25
Price:
Description: Attachment set IC 50-DKR..A DN 350 with shock suppressor /B
IC 50 ACC 26
Price:
Description: Attachment set IC 50-DKR..A DN 400-500 with shock suppressor /B

Latest Blog Post

  • Use the ZI-808 From the Internet
    One of the most exciting features of the ZI-808 is its built-in web server. Its user interface is designed like a standard web page and embedded into the instrument. That means that any device that can open a web page can use it. Desktop, laptop, tablet, smart phone, Android, Windows, iOS, Linux, Edge, IE, Chrome, Firefox. read full post
Combustion 911 Blog Blog Home   Combustion 911 RSS Feed RSS feed
Top