Gas Regulator with Solenoid Valve VAD

Gas Pressure Regulator with Built-in Solenoid Valve VAD 1T20N/NQ-100A

Price:
Quantity:
  • All-purpose servo regulator for gaseous media with integrated solenoid safety valve
  • Suitable for a max. inlet pressure of 500 mbar (500 hPa/7 psig)
  • Minimum installation effort: no external impulse line required
  • ¾&Prime NPT internal thread connection
  • 120 V AC; 50/60 Hz mains voltage
  • 10-100 mbar outlet pressure
  • Normal valve seat
  • Check indication by blue LED
  • Setting options from two sides
  • FM and CSA approved; AGA approved; UL listed
  • Part of the valVario series; Size 1

Applications

Click on images for close-up view.

Application for gas regulator with solenoid valve VAD Constant pressure control

The pressure regulator with gas solenoid valve VAD maintains the set gas outlet pressure pG constant when subject to differing flow rates. If a second gas solenoid valve is used upstream of the VAD, this complies with the requirements of EN 746-2 for two Class A gas solenoid valves connected in series.
Application for gas regulator with solenoid valve VAD Constant pressure control with two gas solenoid valves

The pressure regulator with gas solenoid valve VAD maintains the set gas outlet pressure pG constant when subject to differing flow rates.
Application for gas regulator with solenoid valve VAD Constant pressure control with max. pressure switch

In this example, the minimum inlet pressure pe and the maximum outlet pressure pG are monitored with the pressure switches DG..VCT. The simple attachment of the pressure switch module makes installation easier.
Application for gas regulator with solenoid valve VAD >Constant pressure control with noncontrolled pilot gas outlet

In this application, the pilot burner is supplied with a high inlet pressure via the pilot gas outlet. The simple attachment of the bypass valve module makes installation easier. The minimum inlet pressure pe and the maximum outlet pressure pG are monitored with the pressure switches DG..VCT.

Specifications

General
Types of Gas: natural gas, town gas, LPG (gaseous), biologically produced methane (max. 0.1 %-by-vol. H2S); other gases on request.
The gas must be dry in all temperature conditions and must not contain condensate.
Inlet pressure range pe: 10 – 500 mbar (10 – 500 hPa/4 – 200 "WC), FM approved (230 V AC, 120 V AC, 24 V DC), non operational pressure: 700 mbar (700 hPa/10 psig). CSA approved (230 V AC, 120 V AC, 24 V DC) up to 350 mbar (350 hPa/5 psig).
Opening time of the solenoid valve: quick opening: ≤ 0.5 s.
Closing time: quick closing: < 1 s.
Ambient temperature: -20 to +60°C (-4 to +140°F), no condensation permitted.
Storage temperature: -20 to +40°C (-4 to 104°F), no condensation permitted.
Safety valve: Class A to EN 161, Factory Mutual (FM) Research Class: 410 and 7411
Control range: up to 10:1.
Mains voltage: 230 V AC, +10/-15%, 50/60 Hz;
200 V AC, +10/-15%, 50/60 Hz;
120 V AC, +10/-15%, 50/60 Hz;
100 V AC, +10/-15%, 50/60 Hz;
24 V DC, ±20%.
Cable gland: M20 x 1.5
Electrical connection: electrical cable with max. 2.5 mm2 (AWG 12) or plug with socket to EN 175301-803.
Enclosure: IP 65.
Duty cycle: 100%.
Power factor of the solenoid coil: cos φ = 1.
Power consumption:
Type 24 V DC (W) 100 V AC (W) 120 V AC (W) 200 V AC (W) 230 V AC (W)
Size 1 29 33 30 33 30
Size 2 46 53 54 54 53
Size 3 46 53 54 54 53
Valve housing: aluminium
Valve seal: NBR
Connection flanges with internal thread: Rp to ISO 7-1,
NPT to ANSI/ASME.
Position indicator contact rating:
Type Voltage Min. current (resistive load) Max. current (resistive load)
VAx..S, VCx..S 12 – 250 V AC, 50/60 Hz 100 mA 3 A
VAx..G,
VCx..G
12 – 125 V AC, 50/60 Hz 2 mA 0.1 A
Position indicator switching frequency: max. 5× per minute

Switching
current [A]
Switching cycles*
cos φ = 1 cos φ = 0.6
0.1 500,000 500,000
0.5 300,000 250,000
1 200,000 100,000
3 100,000 --

* Limited to max. 200,000 cycles for heating systems.
Outlet pressure pG: 2.5 – 25 mbar (2.5 – 25 hPa/1 – 10 "WC)
5.0 – 50 mbar (5.0 – 50 hPa/2 – 20 "WC)
10 – 100 mbar (10 – 100 hPa/4 – 40 "WC)

Jump to VAD page

Model:

Click Here for Help choosing which model you need.
(Click here to Close)

Select Connection Type

  All Products
valVario Size 1
valVario Size 2
valVario Size 3
VAD 1T15N/NQ-100B
Price:
Connection: ½″ NPT internal thread; Mains voltage: 120 V AC; 50/60 Hz; Outlet Pressure: 10 – 100 mbar; Valve seat: Reduced; valVario size 1
VAD 1T20N/NQ-100A
Price:
Connection: ¾″ NPT internal thread; Mains voltage: 120 V AC; 50/60 Hz; Outlet Pressure: 10 – 100 mbar; Valve seat: Standard; valVario size 1
VAD 1T25N/NQ-100A
Price:
Connection: 1″ NPT internal thread; Mains voltage: 120 V AC; 50/60 Hz; Outlet Pressure: 10 – 100 mbar; Valve seat: Standard; valVario size 1
VAD 2T40N/NQ-100A
Price:
Connection: 1½″ NPT internal thread; Mains voltage: 120 V AC; 50/60 Hz; Outlet Pressure: 10 – 100 mbar; Valve seat: Standard; valVario size 2
VAD 3T50N/NQ-100A
Price:
Connection: 2″ NPT internal thread; Mains voltage: 120 V AC; 50/60 Hz; Outlet Pressure: 10 – 100 mbar; Valve seat: Standard; valVario size 3

Latest Blog Post

  • Use the ZI-808 From the Internet
    One of the most exciting features of the ZI-808 is its built-in web server. Its user interface is designed like a standard web page and embedded into the instrument. That means that any device that can open a web page can use it. Desktop, laptop, tablet, smart phone, Android, Windows, iOS, Linux, Edge, IE, Chrome, Firefox. read full post
Combustion 911 Blog Blog Home   Combustion 911 RSS Feed RSS feed
Top