Burner Control ESA ALBEN BC

  • One or more gas or oil stage burners without limitation of capacity
  • Single or double flame sensor for pilot and main supervision
  • Flame detection by rod or UV scanner with permanent or non-permanent operation
  • Integrated Valve Proving System
  • High Temperature Operation and Flameless management
  • Packaged burner control
  • Available in two box sizes
  • CSA Approved for the USA and Canada
Burner Control ALBEN

Learn More:
Description   Documentation   Ordering Information   Accessories

Ordering Information

Model and Description Part # Model Expansion Ignition Transformer Mains Voltage Stock Price Cart
ESA ALBEN 110001
ALBEN BC S C//1//////-485ET/////; No expansion; No ignition transformer; 115V Mains Voltage
110001 ALBEN BC S C//1//////-485ET///// No No 115 Vac Contact Us
ESA ALBEN 110007
ALBEN BC S B//1//////-485ET///// ; No expansion; No ignition transformer; 115V Mains Voltage;
110007 ALBEN BC S B//1//////-485ET///// No No 115 Vac Contact Us
ESA ALBEN 110001Q
ALBEN BC S C//1//////-485ET///// ; No expansion; No ignition transformer; 115V Mains Voltage
110001Q ALBEN BC S C//1//////-485ET///// No No 115 Vac Contact Us
ESA ALBEN 110002
ALBEN BC S C//1//////-485ET10/// No expansion; TAR-10 ignition transformer; 115V Mains Voltage
110002 ALBEN BC S C//1//////-485ET10/// No TAR-10 115 Vac Contact Us
ESA ALBEN 110008
ALBEN BC S B//1//////-485ET10/// ; No expansion; TAR-10 ignition transformer; 115V Mains Voltage
110008 ALBEN BC S B//1//////-485ET10/// No TAR-10 115 Vac Contact Us
ESA ALBEN 110002Q
ALBEN BC S C//1//////-485ET10/// ; No expansion; TAR-10 ignition transformer; 115V Mains Voltage
110002Q ALBEN BC S C//1//////-485ET10/// No TAR-10 115 Vac Contact Us
ESA ALBEN 110049
ALBEN BC D C//1D////-485ET/////; Expansion; No ignition transformer; 115V Mains Voltage
110049 ALBEN BC D C//1D////-485ET///// Yes No 115 Vac Contact Us
ESA ALBEN 110089
ALBEN BC D B//1D////-485ET///// ; Expansion; No ignition transformer; 115V Mains Voltage
110089 ALBEN BC D B//1D////-485ET///// Yes No 115 Vac Contact Us
ESA ALBEN 110050
ALBEN BC D C//1D////-485ET10/// ; Expansion; TAR-10 ignition transformer; 115V Mains Voltage
110050 ALBEN BC D C//1D////-485ET10/// Yes TAR-10 115 Vac Contact Us
ESA ALBEN 110090
ALBEN BC D B//1D////-485ET10/// ; Expansion; TAR-10 ignition transformer; 115V Mains Voltage
110090 ALBEN BC D B//1D////-485ET10/// Yes TAR-10 115 Vac Contact Us

Description

The ALBEN BC series identifies automatic burner control units for gas or oil burners.

ALBEN BC is a modular device that allows the management of multiple burner sensors and actuators. Available with two different housings, it can detect flames from two separate flame sensors.

The device safely manages single- or multi-stage burners, monitors combustion air presence, and can detect flame signals from ionization sensors (electrodes) or UV radiation sensors (photocells), continuously checking the flame sensor periodically.

ESA ALBEN is equipped with serial communication for remote burner management, as well as wireless connectivity for effective burner diagnostics and parameterization via a smartphone app.

The robust thermoset or aluminum device housings allow the ESA ALBEN BC installation in the immediate vicinity of the burner. The device can contain the ignition transformer.

ALBEN BS S (in thermoset case)

  • Same form factor as ESTRO
  • Control of a burner up to a two-gas stage
  • Single flame input
  • Air valve control
  • Ignition transformer housing

ALBEN BC D (in aluminum case)

  • Larger than ESTRO (check dimensions in literature)
  • Multi-stage burner control
  • High temperature and flameless self-management
  • Integrate valve proving and packaged burner control
  • Ignition transformer housing

The modularity of ALBEN BC is achieved by combining the ALBEN Safe Unit and AEM01 expansions, resulting in up to five hardware configurations, two of which can be mounted in two types of enclosures.

The ALBEN Safet Unit is the device’s main board, providing safety inputs and outputs for controlling the fuel valves, as well as all the devices for remote and local control.

The AEM01 expansion has additional digital inputs and outputs, in addition to two analog inputs and one analog output. Specifically, the analog inputs can receive thermocouple signals, allowing ALBEN BC to autonomously manage high-temperature operation.

The device allows the configuration of parameters and operating modes according to application needs. When ordering, the behavior of the inputs and outputs can be defined according to pre-established functions. You can also enable/disable process phases and change their timing. It can also define operating sequences based on the type of burner and applicable installation regulations.

ESA ALBEN BC can integrate the fuel valve proving system function (tightness control) or work as an Independent Flame detector instead of burner control.

Accessories

Model and Description Price Cart
Ignition Cable
Silicone Rubber Cable High Voltage 7mm (priced per foot).
 
 

Combustion 911

600 Mogadore Rd. Kent, OH 44240

Phone 330-678-4328

Email: support_ab@combustion911.com

View Terms and Conditions

Privacy Policy

©2026 Olstrad Corporation All Rights Reserved

Visit Combustion 911 on LinkedInVisit Combustion 911 on FacebookVisit Combustion 911 on TwitterWatch Combustion 911 videos on YouTubeEmail Combustion 911Read Articles on the Combustion 911 Blog
Olstrad Corporation

Need a quote? Have a Question?


 
➤