Burner Control ESA ALBEN BC
- One or more gas or oil stage burners without limitation of capacity
- Single or double flame sensor for pilot and main supervision
- Flame detection by rod or UV scanner with permanent or non-permanent operation
- Integrated Valve Proving System
- High Temperature Operation and Flameless management
- Packaged burner control
- Available in two box sizes
- CSA Approved for the USA and Canada

Learn More:
Description Documentation Ordering Information Accessories
Ordering Information
| Model and Description | Stock | Price | Cart |
| ESA ALBEN 110001 ALBEN BC S C//1//////-485ET/////; No expansion; No ignition transformer; 115V Mains Voltage |
Contact Us | ||
| ESA ALBEN 110007 ALBEN BC S B//1//////-485ET///// ; No expansion; No ignition transformer; 115V Mains Voltage; |
Contact Us | ||
| ESA ALBEN 110001Q ALBEN BC S C//1//////-485ET///// ; No expansion; No ignition transformer; 115V Mains Voltage |
Contact Us | ||
| ESA ALBEN 110002 ALBEN BC S C//1//////-485ET10/// No expansion; TAR-10 ignition transformer; 115V Mains Voltage |
Contact Us | ||
| ESA ALBEN 110008 ALBEN BC S B//1//////-485ET10/// ; No expansion; TAR-10 ignition transformer; 115V Mains Voltage |
Contact Us | ||
| ESA ALBEN 110002Q ALBEN BC S C//1//////-485ET10/// ; No expansion; TAR-10 ignition transformer; 115V Mains Voltage |
Contact Us | ||
| ESA ALBEN 110049 ALBEN BC D C//1D////-485ET/////; Expansion; No ignition transformer; 115V Mains Voltage |
Contact Us | ||
| ESA ALBEN 110089 ALBEN BC D B//1D////-485ET///// ; Expansion; No ignition transformer; 115V Mains Voltage |
Contact Us | ||
| ESA ALBEN 110050 ALBEN BC D C//1D////-485ET10/// ; Expansion; TAR-10 ignition transformer; 115V Mains Voltage |
Contact Us | ||
| ESA ALBEN 110090 ALBEN BC D B//1D////-485ET10/// ; Expansion; TAR-10 ignition transformer; 115V Mains Voltage |
Contact Us |
Description
The ALBEN BC series identifies automatic burner control units for gas or oil burners.
ALBEN BC is a modular device that allows the management of multiple burner sensors and actuators. Available with two different housings, it can detect flames from two separate flame sensors.
The device safely manages single- or multi-stage burners, monitors combustion air presence, and can detect flame signals from ionization sensors (electrodes) or UV radiation sensors (photocells), continuously checking the flame sensor periodically.
ESA ALBEN is equipped with serial communication for remote burner management, as well as wireless connectivity for effective burner diagnostics and parameterization via a smartphone app.
The robust thermoset or aluminum device housings allow the ESA ALBEN BC installation in the immediate vicinity of the burner. The device can contain the ignition transformer.
ALBEN BS S (in thermoset case)
- Same form factor as ESTRO
- Control of a burner up to a two-gas stage
- Single flame input
- Air valve control
- Ignition transformer housing
ALBEN BC D (in aluminum case)
- Larger than ESTRO (check dimensions in literature)
- Multi-stage burner control
- High temperature and flameless self-management
- Integrate valve proving and packaged burner control
- Ignition transformer housing
The modularity of ALBEN BC is achieved by combining the ALBEN Safe Unit and AEM01 expansions, resulting in up to five hardware configurations, two of which can be mounted in two types of enclosures.
The ALBEN Safet Unit is the device’s main board, providing safety inputs and outputs for controlling the fuel valves, as well as all the devices for remote and local control.
The AEM01 expansion has additional digital inputs and outputs, in addition to two analog inputs and one analog output. Specifically, the analog inputs can receive thermocouple signals, allowing ALBEN BC to autonomously manage high-temperature operation.
The device allows the configuration of parameters and operating modes according to application needs. When ordering, the behavior of the inputs and outputs can be defined according to pre-established functions. You can also enable/disable process phases and change their timing. It can also define operating sequences based on the type of burner and applicable installation regulations.
ESA ALBEN BC can integrate the fuel valve proving system function (tightness control) or work as an Independent Flame detector instead of burner control.
Documentation
| Burner Control ALBEN Technical Information | |
| ESTRO Replacement Guide | |
| Burner Control ALBEN CSA Certification |
Accessories
| Model and Description | Price | Cart |
| Ignition Cable Silicone Rubber Cable High Voltage 7mm (priced per foot). |