{"id":861,"date":"2022-06-03T15:28:35","date_gmt":"2022-06-03T15:28:35","guid":{"rendered":"https:\/\/www.combustion911.com\/blog\/?p=861"},"modified":"2022-07-15T15:51:04","modified_gmt":"2022-07-15T15:51:04","slug":"how-to-wire-an-elektrogas-proof-of-closure-device","status":"publish","type":"post","link":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/","title":{"rendered":"How to Wire an Elektrogas Proof of Closure Device"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-4-3 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Wiring Your Elektrogas Proof of Closure Device\" width=\"500\" height=\"375\" src=\"https:\/\/www.youtube.com\/embed\/RmBG4rODPmQ?start=21&#038;feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p>We&#8217;ve created a video demonstration to help users wire a DIN plug for an <a href=\"https:\/\/www.combustion911.com\/products\/industrial-gas-valves\/solenoid\/vmr-vml\/\">Elektrogas<\/a> Proof of Closure device. The numbers in this blog correspond with the numbers in the video.<\/p>\n\n\n\n<p>1. Once you\u2019ve unscrewed the plug and removed it from the proof of closure device, step one is to remove the rubber gasket and set it aside.&nbsp;<\/p>\n\n\n\n<p>2. Next, remove the screw. You will alternately push and pull the screw out of the plug. The inside of the plug isn\u2019t threaded, so you don\u2019t need to use a screwdriver in this step. <\/p>\n\n\n\n<p>3. You will need a small, flat-bladed screwdriver to pop the connection block out of the plug housing.<\/p>\n\n\n\n<p>4.&nbsp;The connection block is where you will install your wires. Push the wires through the plug housing before installing them to the connection block.&nbsp; Use your small screwdriver to loosen the screws you find on the connection block \u2014 all except the one marked with the Ground symbol.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/04\/schematic-v2-01.png\"><img loading=\"lazy\" decoding=\"async\" width=\"2550\" height=\"1442\" src=\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/04\/schematic-v2-01.png\" alt=\"DIN plug schematic\" class=\"wp-image-901\"\/><\/a><figcaption>Schematic also appears in the video<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Schematic<\/h2>\n\n\n\n<p>5. This is the drawing found in the Elektrogas literature. The designations found on the right; 1, 2, 3, and COM, correspond to the markings on the connection block. <\/p>\n\n\n\n<p>One is hot, Two is \u201cvalve open,\u201d Three is \u201cvalve closed,\u201d and the terminal marked \u201cCOM\u201d is neutral in this case<\/p>\n\n\n\n<p>The connection block contains a two-tone LED, to provide visual indication of the valve\u2019s position. Once wired, powered, and connected to the proof of closure device, a red light means the valve is open; a green light means the valve is closed.<\/p>\n\n\n\n<p>With the wiring complete, it\u2019s time to reinstall the connection block in the plug housing. Feed the wires back through the plug housing until you can pop the connection block in place.<\/p>\n\n\n\n<p>6. Proper installation of these three components keeps moisture from entering the plug housing. The rubber gasket must come first, followed by the metal washer, and finally the nylon nut.&nbsp;When using SO cord, keep openings in the insulated jacket on the terminal side of the rubber gasket. Any cuts in the insulated jacket which are on the other side of the gasket will allow moisture to enter the plug housing.<\/p>\n\n\n\n<p>&nbsp;Replace the screw and gasket to complete your plug assembly.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"> For automation<\/h2>\n\n\n\n<p>Visit&nbsp;<a href=\"http:\/\/olstrad.com\/\">olstrad.com<\/a>&nbsp;to learn more about our automation processes!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>We&#8217;ve created a video demonstration to help users wire a DIN plug for an Elektrogas Proof of Closure device. The numbers in this blog correspond with the numbers in the video. 1. Once you\u2019ve unscrewed the plug and removed it from the proof of closure device, step one is to remove the rubber gasket and <a class=\"read-more\" href=\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/\">Read More<\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[107,49],"tags":[112,100,144,55],"class_list":["post-861","post","type-post","status-publish","format-standard","hentry","category-elektrogas","category-faqs","tag-combustion","tag-elektrogas","tag-faq","tag-proof-of-closure"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>DIN Plug wiring for Elektrogas Proof of Closure device<\/title>\n<meta name=\"description\" content=\"In this blog post we demonstrate the correct way to wire a DIN plug for Elektrogas proof of closure devices.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"b-olstrad\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/\"},\"author\":{\"name\":\"b-olstrad\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e\"},\"headline\":\"How to Wire an Elektrogas Proof of Closure Device\",\"datePublished\":\"2022-06-03T15:28:35+00:00\",\"dateModified\":\"2022-07-15T15:51:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/\"},\"wordCount\":408,\"image\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/04\/schematic-v2-01.png\",\"keywords\":[\"combustion\",\"Elektrogas\",\"faq\",\"Proof of Closure\"],\"articleSection\":[\"Elektrogas\",\"FAQs\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/\",\"url\":\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/\",\"name\":\"DIN Plug wiring for Elektrogas Proof of Closure device\",\"isPartOf\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/04\/schematic-v2-01.png\",\"datePublished\":\"2022-06-03T15:28:35+00:00\",\"dateModified\":\"2022-07-15T15:51:04+00:00\",\"author\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e\"},\"description\":\"In this blog post we demonstrate the correct way to wire a DIN plug for Elektrogas proof of closure devices.\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/#primaryimage\",\"url\":\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/04\/schematic-v2-01.png\",\"contentUrl\":\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/04\/schematic-v2-01.png\",\"width\":2550,\"height\":1442},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/#website\",\"url\":\"https:\/\/www.combustion911.com\/blog\/\",\"name\":\"Combustion 911\",\"description\":\"Combustion Systems and Spare Parts\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.combustion911.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e\",\"name\":\"b-olstrad\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/459452034e9edd910d0438e2f949d205ea425ad0ce52460e64734a59c72888d6?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/459452034e9edd910d0438e2f949d205ea425ad0ce52460e64734a59c72888d6?s=96&d=mm&r=g\",\"caption\":\"b-olstrad\"},\"sameAs\":[\"http:\/\/www.combustion911.com\"],\"url\":\"https:\/\/www.combustion911.com\/blog\/author\/b-olstrad\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"DIN Plug wiring for Elektrogas Proof of Closure device","description":"In this blog post we demonstrate the correct way to wire a DIN plug for Elektrogas proof of closure devices.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/","twitter_misc":{"Written by":"b-olstrad","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/#article","isPartOf":{"@id":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/"},"author":{"name":"b-olstrad","@id":"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e"},"headline":"How to Wire an Elektrogas Proof of Closure Device","datePublished":"2022-06-03T15:28:35+00:00","dateModified":"2022-07-15T15:51:04+00:00","mainEntityOfPage":{"@id":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/"},"wordCount":408,"image":{"@id":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/#primaryimage"},"thumbnailUrl":"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/04\/schematic-v2-01.png","keywords":["combustion","Elektrogas","faq","Proof of Closure"],"articleSection":["Elektrogas","FAQs"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/","url":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/","name":"DIN Plug wiring for Elektrogas Proof of Closure device","isPartOf":{"@id":"https:\/\/www.combustion911.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/#primaryimage"},"image":{"@id":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/#primaryimage"},"thumbnailUrl":"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/04\/schematic-v2-01.png","datePublished":"2022-06-03T15:28:35+00:00","dateModified":"2022-07-15T15:51:04+00:00","author":{"@id":"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e"},"description":"In this blog post we demonstrate the correct way to wire a DIN plug for Elektrogas proof of closure devices.","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.combustion911.com\/blog\/faqs\/how-to-wire-an-elektrogas-proof-of-closure-device\/#primaryimage","url":"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/04\/schematic-v2-01.png","contentUrl":"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/04\/schematic-v2-01.png","width":2550,"height":1442},{"@type":"WebSite","@id":"https:\/\/www.combustion911.com\/blog\/#website","url":"https:\/\/www.combustion911.com\/blog\/","name":"Combustion 911","description":"Combustion Systems and Spare Parts","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.combustion911.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e","name":"b-olstrad","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/459452034e9edd910d0438e2f949d205ea425ad0ce52460e64734a59c72888d6?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/459452034e9edd910d0438e2f949d205ea425ad0ce52460e64734a59c72888d6?s=96&d=mm&r=g","caption":"b-olstrad"},"sameAs":["http:\/\/www.combustion911.com"],"url":"https:\/\/www.combustion911.com\/blog\/author\/b-olstrad\/"}]}},"_links":{"self":[{"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/posts\/861","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/comments?post=861"}],"version-history":[{"count":11,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/posts\/861\/revisions"}],"predecessor-version":[{"id":1065,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/posts\/861\/revisions\/1065"}],"wp:attachment":[{"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/media?parent=861"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/categories?post=861"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/tags?post=861"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}