{"id":660,"date":"2022-01-13T13:29:07","date_gmt":"2022-01-13T13:29:07","guid":{"rendered":"https:\/\/www.combustion911.com\/blog\/?p=660"},"modified":"2022-01-13T13:38:05","modified_gmt":"2022-01-13T13:38:05","slug":"adapt-iso-plugs-to-elektrogas-valves","status":"publish","type":"post","link":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/","title":{"rendered":"FAQ: Adapting ISO Plugs to Elektrogas Valves"},"content":{"rendered":"\n<p><strong>Q: <\/strong>Can you adapt ISO plugs to Elektrogas valves?<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2.jpg\" alt=\"\" class=\"wp-image-661\" width=\"327\" height=\"303\"\/><\/a><figcaption>PG9-1\/2NPT Adapter<\/figcaption><\/figure><\/div>\n\n\n\n<p><strong>A<\/strong>: We\u2019ve supplied dozens of customers with <a href=\"https:\/\/www.combustion911.com\/elektrogas.html\">Elektrogas<\/a> valves for retrofit applications, and we understand the challenges associated with installing a valve that is a little different, whether the difference is in the physical dimensions, or in the electrical connection. We stock Elektrogas solenoid valves with electrical connection via plug and socket (conforming to the following norms: DIN 43650A; ISO 4400; EN 175301-803 A) because in our experience, these plugs are more accessible for the wire gauges common in the USA, as opposed to using the terminals in the electrical housing on the valve, which were designed with smaller European wire sizes in mind.<\/p>\n\n\n\n<p>If you\u2019re using SO cord, there\u2019s no problem. But things can get a little complicated when your wire run is inside conduit, whether rigid or flexible. The plug included with each (relevant) Elektrogas solenoid valve has PG9 female thread, and most conduit runs to these valves will be in a \u00bd\u201d size, terminating in NPT (male). The solution is our PG9-1\/2NPT conduit adapter, which allows you to adapt ISO plugs to Elektrogas valves.<\/p>\n\n\n\n<div class=\"wp-block-image is-style-default\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2NPT_FAQ_v2.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2NPT_FAQ_v2.jpg\" alt=\"\" class=\"wp-image-664\" width=\"574\" height=\"383\"\/><\/a><\/figure><\/div>\n\n\n\n<p>Remember, the orientation of the plug can be easily changed. Just remove the screw, pop the plate out with a small screwdriver, rotate, and pop it back in.&nbsp;<\/p>\n\n\n\n<p>PG9-1\/2NPT should appear in the Accessories sections of safety shut-off valves <a href=\"https:\/\/www.combustion911.com\/products\/industrial-gas-valves\/solenoid\/vmr-vml\/\">VMR<\/a>, <a href=\"https:\/\/www.combustion911.com\/products\/industrial-gas-valves\/solenoid\/vmr-vml\/\">VML<\/a>, <a href=\"https:\/\/www.combustion911.com\/products\/industrial-gas-valves\/solenoid\/vmm\/\">VMM<\/a>, and <a href=\"https:\/\/www.combustion911.com\/products\/industrial-gas-valves\/solenoid\/vmr-otn\/\">VMR..OTN<\/a>; solenoid valves for air <a href=\"https:\/\/www.combustion911.com\/products\/industrial-gas-valves\/solenoid\/vra-vla-vta\/\">VRA\/VLA\/VTA<\/a>; normally open vent valves <a href=\"https:\/\/www.combustion911.com\/products\/industrial-gas-valves\/vent\/vmrna\/\">VMRNA<\/a>; and solenoid actuator for butterfly valves <a href=\"https:\/\/www.combustion911.com\/products\/actuators\/sr-sl-st\/\">SR\/SL\/ST<\/a>. Installation of gas equipment must be performed by qualified technicians only, and in compliance with local and national codes. As always, please <a href=\"https:\/\/www.combustion911.com\/company\/contact\/\">contact us<\/a> with questions!<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/FAQ_Attach.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/FAQ_Attach.jpg\" alt=\"\" class=\"wp-image-662\" width=\"581\" height=\"388\"\/><\/a><\/figure><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Q: Can you adapt ISO plugs to Elektrogas valves? A: We\u2019ve supplied dozens of customers with Elektrogas valves for retrofit applications, and we understand the challenges associated with installing a valve that is a little different, whether the difference is in the physical dimensions, or in the electrical connection. We stock Elektrogas solenoid valves with <a class=\"read-more\" href=\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/\">Read More<\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[49,1],"tags":[],"class_list":["post-660","post","type-post","status-publish","format-standard","hentry","category-faqs","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Adapt ISO Plugs to Elektrogas Valves<\/title>\n<meta name=\"description\" content=\"How to adapt ISO plugs to Elektrogas valves\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"b-olstrad\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/\"},\"author\":{\"name\":\"b-olstrad\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e\"},\"headline\":\"FAQ: Adapting ISO Plugs to Elektrogas Valves\",\"datePublished\":\"2022-01-13T13:29:07+00:00\",\"dateModified\":\"2022-01-13T13:38:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/\"},\"wordCount\":295,\"image\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2.jpg\",\"articleSection\":[\"FAQs\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/\",\"url\":\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/\",\"name\":\"Adapt ISO Plugs to Elektrogas Valves\",\"isPartOf\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2.jpg\",\"datePublished\":\"2022-01-13T13:29:07+00:00\",\"dateModified\":\"2022-01-13T13:38:05+00:00\",\"author\":{\"@id\":\"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e\"},\"description\":\"How to adapt ISO plugs to Elektrogas valves\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/#primaryimage\",\"url\":\"http:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2.jpg\",\"contentUrl\":\"http:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2.jpg\"},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/#website\",\"url\":\"https:\/\/www.combustion911.com\/blog\/\",\"name\":\"Combustion 911\",\"description\":\"Combustion Systems and Spare Parts\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.combustion911.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e\",\"name\":\"b-olstrad\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/459452034e9edd910d0438e2f949d205ea425ad0ce52460e64734a59c72888d6?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/459452034e9edd910d0438e2f949d205ea425ad0ce52460e64734a59c72888d6?s=96&d=mm&r=g\",\"caption\":\"b-olstrad\"},\"sameAs\":[\"http:\/\/www.combustion911.com\"],\"url\":\"https:\/\/www.combustion911.com\/blog\/author\/b-olstrad\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Adapt ISO Plugs to Elektrogas Valves","description":"How to adapt ISO plugs to Elektrogas valves","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/","twitter_misc":{"Written by":"b-olstrad","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/#article","isPartOf":{"@id":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/"},"author":{"name":"b-olstrad","@id":"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e"},"headline":"FAQ: Adapting ISO Plugs to Elektrogas Valves","datePublished":"2022-01-13T13:29:07+00:00","dateModified":"2022-01-13T13:38:05+00:00","mainEntityOfPage":{"@id":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/"},"wordCount":295,"image":{"@id":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/#primaryimage"},"thumbnailUrl":"http:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2.jpg","articleSection":["FAQs"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/","url":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/","name":"Adapt ISO Plugs to Elektrogas Valves","isPartOf":{"@id":"https:\/\/www.combustion911.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/#primaryimage"},"image":{"@id":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/#primaryimage"},"thumbnailUrl":"http:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2.jpg","datePublished":"2022-01-13T13:29:07+00:00","dateModified":"2022-01-13T13:38:05+00:00","author":{"@id":"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e"},"description":"How to adapt ISO plugs to Elektrogas valves","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.combustion911.com\/blog\/faqs\/adapt-iso-plugs-to-elektrogas-valves\/#primaryimage","url":"http:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2.jpg","contentUrl":"http:\/\/www.combustion911.com\/blog\/wp-content\/uploads\/2022\/01\/PG9-1_2.jpg"},{"@type":"WebSite","@id":"https:\/\/www.combustion911.com\/blog\/#website","url":"https:\/\/www.combustion911.com\/blog\/","name":"Combustion 911","description":"Combustion Systems and Spare Parts","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.combustion911.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/65f917e4b2ad5b4feb720af326b6803e","name":"b-olstrad","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.combustion911.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/459452034e9edd910d0438e2f949d205ea425ad0ce52460e64734a59c72888d6?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/459452034e9edd910d0438e2f949d205ea425ad0ce52460e64734a59c72888d6?s=96&d=mm&r=g","caption":"b-olstrad"},"sameAs":["http:\/\/www.combustion911.com"],"url":"https:\/\/www.combustion911.com\/blog\/author\/b-olstrad\/"}]}},"_links":{"self":[{"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/posts\/660","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/comments?post=660"}],"version-history":[{"count":8,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/posts\/660\/revisions"}],"predecessor-version":[{"id":679,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/posts\/660\/revisions\/679"}],"wp:attachment":[{"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/media?parent=660"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/categories?post=660"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.combustion911.com\/blog\/wp-json\/wp\/v2\/tags?post=660"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}