Industrial Burner for Gas BIO

Industrial Burner for Gas BIOThe BIO burner is designed for industrial furnaces and firing systems in the iron and steel industries in the precious, non-ferrous, and light metal sector, as well as in the plastics, fiber, and paper industries. Other fields of application are thermal incineration installations, as well as dryers and hot-air generators.

For low temperature applications (e.g. for crucible heating, radiant tube heating, or hot-air generation), the burners are equipped with a heat-resistant steel attachment tube.

For high temperature applications (e.g. forging furnace), the burners are used in combination with a burner quarl made from refractory concrete. Different flame shapes can be achieved by using burner quarls with a different geometry.

The burner can be adapted to the system requirements using different burner tube lengths.

Features

  • Large capacity range up to 1000 kW
  • Maintenance-friendly thanks to modular design
  • Robust burner design
  • Direct or lance ignition
  • Control via ionization or UV sensor
  • Suitable for new systems and modernization of existing systems thanks to individual length adjustment
  • Air preheating to 450°C available as an option
  • Low polluting level thanks to optimized combustion
  • For installation as ceiling or side-wall burner thanks to arbitrary installation position
  • Can be combined with different combustion chamber shapes
Documentation for Burner BIO

Documentation

Manufacturer's Product Brochure
Manufacturer's Operating Instructions
Manufacturer's Technical Sheet

 
Ordering information for Burner BIO

Ordering Information

Model Burner Size Flame Shape Gas Type Length of Burner Tube Position of Burner Head Burner Head ID Construction Stage Price
(US List)
Order Now
BIO 50HB-50/35-(27)C 50 Long Natural Gas 50 35 27 C Contact Combustion 911
BIO 50HB-100/35-(11)C 50 Long Natural Gas 100 35 11 C Contact Combustion 911
BIO-50RB-150/135-(27)B 50 Normal Natural Gas 150 135 27 B Contact Combustion 911
BIO 50HB-200/135-(11)C 50 Long Natural Gas 200 135 11 C Contact Combustion 911
BIO 50RB-250/235-(27)B 50 Normal Natural Gas 250 235 27 B Contact Combustion 911
BIO 50HB-300/235-(11)C 50 Long Natural Gas 300 235 11 C Contact Combustion 911
BIO 50RB-350/335-(27)B 50 Normal Natural Gas 350 335 27 B Contact Combustion 911
BIO 50HB-400/335-(11)C 50 Long Natural Gas 400 335 11 C Contact Combustion 911
BIO 50RB-450/435-(27)B 50 Normal Natural Gas 450 435 27 B Contact Combustion 911
BIO 50HB-500/435-(11)C 50 Long Natural Gas 500 435 11 C Contact Combustion 911
BIO 65RB-50/35-(37)E 65 Normal Natural Gas 50 35 37 E Contact Combustion 911
BIO 65RB-150/135-(37)E 65 Normal Natural Gas 150 135 37 E Contact Combustion 911
BIO 65RB-250/235-(37)E 65 Normal Natural Gas 250 235 37 E Contact Combustion 911
BIO 65RB-350/335-(37)E 65 Normal Natural Gas 350 335 37 E Contact Combustion 911
BIO 65RB-450/435-(37)E 65 Normal Natural Gas 450 435 37 E Contact Combustion 911
BIO 65HB-100/35-(34)E 65 Long Natural Gas 100 35 34 E Contact Combustion 911
BIO 65HB-200/135-(34)E 65 Long Natural Gas 200 135 34 E Contact Combustion 911
BIO 65HB-300/235-(34)E 65 Long Natural Gas 300 235 34 E Contact Combustion 911
BIO 65HB-400/335-(34)E 65 Long Natural Gas 400 335 34 E Contact Combustion 911
BIO 65HB-500/435-(34)E 65 Long Natural Gas 500 435 34 E Contact Combustion 911
BIO 80RB-50/35-(6)E 80 Normal Natural Gas 50 35 6 E Contact Combustion 911
BIO 80RB-150/135-(6)E 80 Normal Natural Gas 150 135 6 E Contact Combustion 911
BIO 80RB-250/235-(6)E 80 Normal Natural Gas 250 235 6 E Contact Combustion 911
BIO 80RB-350/335-(6)E 80 Normal Natural Gas 350 335 6 E Contact Combustion 911
BIO 80RB-450/435-(6)E 80 Normal Natural Gas 450 435 6 E Contact Combustion 911
BIO 80HB-100/35-(16)F 80 Long Natural Gas 100 35 16 F Contact Combustion 911
BIO 80HB-200/135-(16)F 80 Long Natural Gas 200 135 16 F Contact Combustion 911
BIO 80HB-300/235-(16)F 80 Long Natural Gas 300 235 16 F Contact Combustion 911
BIO 80HB-400/335-(16)F 80 Long Natural Gas 400 335 16 F Contact Combustion 911
BIO 80HB-500/435-(16)F 80 Long Natural Gas 500 435 16 F Contact Combustion 911
BIO 100RB-50/35-(70)E 100 Normal Natural Gas 50 35 70 E Contact Combustion 911
BIO 100RB-150/135-(70)E 100 Normal Natural Gas 150 135 70 E Contact Combustion 911
BIO 100RB-250/235-(70)E 100 Normal Natural Gas 250 235 70 E Contact Combustion 911
BIO 100RB-350/335-(70)E 100 Normal Natural Gas 350 335 70 E Contact Combustion 911
BIO 100RB-450/435-(70)E 100 Normal Natural Gas 450 435 70 E Contact Combustion 911
BIO 100HB-100/35-(37)E 100 Long Natural Gas 100 35 37 E Contact Combustion 911
BIO 100HB-200/135-(37)E 100 Long Natural Gas 200 135 37 E Contact Combustion 911
BIO 100HB-300/235-(37)E 100 Long Natural Gas 300 235 37 E Contact Combustion 911
BIO 100HB-400/335-(37)E 100 Long Natural Gas 400 335 37 E Contact Combustion 911
BIO 100HB-500/435-(37)E 100 Long Natural Gas 500 435 37 E Contact Combustion 911
BIO 125HB-100/35-(2)D 125 Long Natural Gas 100 35 2 D Contact Combustion 911
BIO 125RB-50/35-(1)D 125 Normal Natural Gas 50 35 1 D Contact Combustion 911
BIO 125HB-200/135-(2)D 125 Long Natural Gas 200 135 2 D Contact Combustion 911
BIO 125RB-150/135-(1)D 125 Normal Natural Gas 150 135 1 D Contact Combustion 911
BIO 125HB-300/235-(2)D 125 Long Natural Gas 300 235 2 D Contact Combustion 911
BIO 125RB-250/235-(1)D 125 Normal Natural Gas 250 235 1 D Contact Combustion 911
BIO 125HB-400/335-(2)D 125 Long Natural Gas 400 335 2 D Contact Combustion 911
BIO 125RB-350/335-(1)D 125 Normal Natural Gas 350 335 1 D Contact Combustion 911
BIO 125HB-500/435-(2)D 125 Long Natural Gas 500 435 2 D Contact Combustion 911
BIO 125RB-450/335-(1)D 125 Normal Natural Gas 450 335 1 D Contact Combustion 911
BIO 140RB-50/35-(47)E 140 Normal Natural Gas 50 35 47 E Contact Combustion 911
BIO 140RB-150/135-(47)E 140 Normal Natural Gas 150 135 47 E Contact Combustion 911
BIO 140RB-250/235-(47)E 140 Normal Natural Gas 250 235 47 E Contact Combustion 911
BIO 140RB-350/335-(47)E 140 Normal Natural Gas 350 335 47 E Contact Combustion 911
BIO 140RB-450/435-(47)E 140 Normal Natural Gas 450 435 47 E Contact Combustion 911
BIO 140HB-100/35-(26)E 140 Long Natural Gas 100 35 26 E Contact Combustion 911
BIO 140HB-200/135-(26)E 140 Long Natural Gas 200 135 26 E Contact Combustion 911
BIO 140HB-300/235-(26)E 140 Long Natural Gas 300 235 26 E Contact Combustion 911
BIO 140HB-400/335-(26)E 140 Long Natural Gas 400 335 26 E Contact Combustion 911
BIO 140HB-500/435-(26)E 140 Long Natural Gas 500 435 26 E Contact Combustion 911
For all other configurations and spare parts Contact Combustion 911
 
Applications for Burner BIO

Applications

Click on images for close-up view.

Application for Burner BIO and ZIO Continuous control with pneumatic ratio control system

This type of control offers the benefit of the mixture setting being maintained over a wide control range while at the same time preventing air deficiency. This type of control is used in melting furnaces in the aluminium industry or in regenerative incineration installations in the environmental industry, for example.
Application for Burner BIO and ZIO Continuous control with pneumatic ratio control system and lance

The burner’s flexibility is increased thanks to an ignition lance. The control range can be extended incrementally with an optional integrated lance. This type of control is used in heat treatment furnaces in the iron and non-ferrous metal industries and in heating furnaces in the steel industry, for example.
Application for Burner BIO and ZIO Continuous control with pneumatic ratio control system

The burner is designed for near-stoichiometrical operation and a control range of 1:10 with its special burner head construction for CO2-optimised combustion. In combination with the cascade control system, the burner is capable of operating even with very low connection ratings, control ranges of 1:45 can be achieved.
Application for Burner BIO and ZIO Staged control with pneumatic ratio control system

The high output pulse at the burner generated by this type of control produces a uniform temperature distribution and good circulation of the furnace or kiln atmosphere, e.g. in heat treatment furnaces in the iron and non-ferrous metal industries or kilns for heavy-clay and fine ceramics. The pneumatic air/gas ratio control system offers maximum safety by an air deficiency cut-out, with a constant lambda value being maintained while the air pressure varies.
 
Specifications for Burner BIO

Specifications

General Specifications
Gas supply pressure: approx. 20 to 60 mbar
Air supply pressure: approx. 25 to 40 mbar, each depending on flame shape and gas type (gas and air pressures
Burner length increments: 100 mm
Types of gas: natural gas or LPG (gaseous); other gases on request
Heating: direct using a burner quarl or an attachment tube, indirect using a burner attachment tube inside the radiant tube.
Control type: staged: On/Off, High/Low/Off,
continuous: constant λ value.
Housing: BIO: GG25
BIOA: AlSi
ZIO: ST
Flame control: direct ionisation control (UV control as an option)
Ignition: direct, electrical, lance as an option
Maximum furnace temperature: BIO/ZIO in burner quarl: up to 1600°C, with K burner head: up to 1100°C (higher temperatures on request),
BIO/ZIO with burner attachment tube: up to 800°C (higher temperatures on request).
Maximum air temperature: BIO, ZIO: 450°C
BIOA: 200°C
Maintenance cycle: Twice per year, but if the media are highly contaminated, this interval should be reduced.

Industrial Burner for Gas BIO 140
Burner BIO 140